Millipore Sigma Webinar
 

Charles River Introduces PTS Gram ID for Gram Stain Results in 3 Minutes

PTS Gram ID

The Gram stain assay has been used routinely to classify bacteria in microbiology laboratories for over 160 years. Since the Gram stain is often the first test for a complete bacterial identification, the cost of erroneous Gram stain results is magnified. Charles River Laboratories now offers the Endosafe™ -PTS Gram ID, a definitive point-of-use test that decreases the variability and technician time associated with the Gram stain assay.

The PTS Gram ID is a revolutionary new assay that utilizes a hand-held reader and disposable cartridge pre-loaded with all of the materials needed to run a single-step Gram determination.

Test Technology
The PTS Gram ID is a fast, simple test that measures the presence of the cell walls in a microbial isolate. The measurement is interpreted by the software to indicate whether a sample contains Gram negative or positive bacteria or yeasts/molds.

The PTS Gram ID eliminates technician variability that can occur in a Gram stain determination that uses multiple reagent steps. The PTS also reduces the chances for incorrect or Gram-variable results that occur due to physiological properties of the cell wall. The PTS makes identifications based on the composition of the cell walls only, not the presence of dyes picked up by the cell walls. Over 70 different organisms have been tested with the PTS Gram ID for accuracy and specificity.

Test Procedure
To perform the test, the user simply loads a different sample into each of the four sample reservoirs of the disposable cartridge. The reader draws and mixes the sample and measures the optical density of the reaction. Within about 3 minutes, the PTS will indicate if the sample organism is Gram negative or Gram positive. The test will also identify yeast/mold in about 7 minutes.

There is no subjectivity or interpretation of results. Up to 100 results can be saved in memory and can be downloaded to lab management software for documentation or printed directly from the reader. The technician time to perform a Gram determination is greatly reduced with the PTS Gram ID and there is minimal training required. In addition, there are no stains to handle or dispose of, no slides to dry or heat fix and no microscopic assessment required.

The PTS has been used effectively for testing organisms that were 72 hours, reducing the need for sub-culturing. The PTS Gram ID eliminates the need for confirmation tests such as KOH or MacConkey plates. The PTS reader is a platform that can be used for other microbiological testing including LAL analysis and other applications currently in development.


NOTE: This item is from our 'historic' database and may contain information which is not up to date.

Source : Charles River Laboratories International, Inc. View Company Information

Posted on February 22, 2005



Fijifilm Pyrostar testing critical water used in the reprocessing of medical devices
 

SGL Plates and Culture Media for Pharmaceutical Microbiology
 

AI for microbiology
 

QC Standards Controls and Proficiency Testing Schemes
 

Get our eNewsletter
Over 7,000 microbiology professionals get our weekly eNewsletter - subscribe now and find out why!

LATEST MICROBIOLOGY NEWS

MICROBIOLOGY EVENTS